worldwide@absin.cn
  • Sign in or Register
    My account Recent orders Wish list Address management

    Sign out

  • Cart 0
    The latest additions

      0 items in total

      Subtotal $0.00

      Go to cart
    • English
      Chinese
    爱必信(absin)官网
    爱必信(absin)官网

    000000 Citations

    Home
    Products
    Promotions
    Resources
    Product ApplicationFAQsNewsCitationsElectronic DocumentsCalculation Tools
    About us
    Contact us
    worldwide@absin.cn
    • Sign in or Register
      My account Recent orders Wish list Address management

      Sign out

    • Cart 0
      The latest additions

        0 items in total

        Subtotal $0.00

        Go to cart
      • English
        Chinese
      爱必信(absin)官网
      爱必信(absin)官网

      000000 Citations

      Home
      Products
      Promotions
      Resources
      Product ApplicationFAQsNewsCitationsElectronic DocumentsCalculation Tools
      About us
      Contact us
      HomeProduct ApplicationFollow these steps to ensure smooth usage of the matrix gel.
      Search

      Follow these steps to ensure smooth usage of the matrix gel.

      June 18, 2025

      Clicks:1061

      Share:
      Share This on facebook
      Share This on twitter
      Share This on pinterest
      Share This on linkedin
      Share This on skype
      Share This on telegram
      Share This on whatsapp
      Share This on wechat

      一、Upon Receipt, Please Check

      1.  Whether there is dry ice in the foam box;
      2.  If the matrix gel is solid and the surface is smooth;
      3.  If the color of the matrix gel is within the normal range (white/milky white without phenol red, yellow-pink-dark red with phenol red, determined by temperature changes);
      4.  If you do not plan to use the matrix gel immediately upon receipt, store it in a -20/-80°C refrigerator for long-term preservation.

      二、Operational Procedure Description

      Before using the matrix gel each time, thaw it strictly according to the following procedure!

      1、Pre-cool the "Matrix Gel Ice Box (abs7289)" (or prepare crushed ice) and a 200μL pipette tip box for more than 1 hour at -20°C. Before leaving work in the evening, take the matrix gel out of the -20/-80°C refrigerator and place it in the "Matrix Gel Ice Box" (or bury it in an ice box filled with crushed ice), then place the entire ice box in a 4°C refrigerator for overnight thawing;

      2、The next day, after thawing is complete, you can use the matrix gel. Take the matrix gel out of the 4°C refrigerator and immediately place it in a pre-cooled -20°C "Matrix Gel Aliquot Ice Box" (ice box with crushed ice), then use it aseptically on a laminar flow hood/biosafety cabinet;

      3、When using, take out the pre-cooled 200μL pipette tips from -20°C and open the matrix gel bottle cap (try to operate on the matrix gel thawing ice box);

      4、After using the matrix gel, immediately put it back in the ice box and store it in a 4°C refrigerator for short-term preservation, use it up within two weeks.

       

      三、Essential Notes

      1、Do not directly contact the matrix gel with the palm of your hand;

      2、The entire usage process should be carried out on the pre-cooled matrix gel aliquot ice box (ice box with crushed ice), and the remaining matrix gel can be stored at 4°C for up to two weeks;

      3、Never directly throw the matrix gel in the refrigerator for thawing and storage, always place it in the "Matrix Gel Ice Box" (or bury it in an ice box filled with crushed ice) before putting it in the 4°C refrigerator for thawing or storage; in addition, do not thaw or store it near the refrigerator door, or in a refrigerator that is often opened to take out reagents, try to thaw or store it inside/drawer of the 4°C refrigerator/air outlet;

      4、Since the matrix gel is sensitive to temperature, it is recommended to use a non-defrost type and stable temperature refrigerator for melting and storage, never thaw the matrix gel in a refrigerator with automatic defrosting;

      5、If using an ice box for overnight thawing, fix the position of the matrix gel bottle to ensure that the bottle will not tip over after the ice melts overnight, and the ice water will not submerge the matrix gel bottle mouth;

      6、Avoid repeated freeze-thaw cycles during the use of the matrix gel;

      7、Liquid matrix gel will quickly solidify above 8°C (especially high-concentration matrix gel). Therefore, when using, the consumables in contact with the matrix gel must be pre-cooled (such as pipettes, tips, EP tubes, etc.), and the entire experiment must be operated aseptically on ice;

      8、The matrix gel on ice should be in a liquid state when using, if the matrix gel has already solidified on ice, it indicates that the aliquot operation failed to maintain low temperature, causing the matrix gel to solidify, and should not be used again;

      9、If you find that the matrix gel in the 4°C refrigerator is very viscous but still liquid, you can place it in a pre-cooled -20°C ice box, put it in the -20°C refrigerator for 3-5 minutes, and the fluidity will generally return to normal; if it cannot be restored, it may be due to the refrigerator temperature being too high causing gelation, it is recommended not to use it.

       

      四、Q&A

      Q1: Why is my matrix gel very viscous?
      A1: The higher the protein concentration of the matrix gel, the more viscous the gel. If the concentration is higher than 13.0mg/mL, the matrix gel will be very thick. Matrix gel products are relatively viscous before dilution. The viscous high-concentration matrix gel can be used directly without dilution, such as for culturing tumor cells and/or angiogenic factors, injected into mice, cells can remain in place, facilitating in situ analysis and/or later excision; or diluted, used according to the standard concentration matrix gel product usage method, the specific dilution concentration is determined according to experimental needs.
      A2: In addition to the product itself being highly concentrated and viscous, the state of the matrix gel is also related to temperature changes during transportation and storage conditions. Dry ice must be used throughout the transportation process. If the refrigerator where the matrix gel is stored has an automatic defrosting function, the temperature may rise during the defrosting process, causing the matrix gel to solidify. Therefore, never store matrix gel in such refrigerators with automatic defrosting. To ensure the effectiveness of the matrix gel, the number of freeze-thaw cycles should be minimized. Special attention: the temperature transfer of water, ice, ice water, and air is different, the air temperature transfer is particularly slow and the temperature distribution is uneven, therefore, the matrix gel thawing cannot be directly thrown in the 2-8°C refrigerator to thaw, it must be placed in an ice box/ice water mixture, then put in the 0-4°C refrigerator to thaw.

       

      五、Buy Matrix Gel and Get a Scratch Card Activity is Still Ongoing

      For the event, please visit: Matrix Gel Accompanies You Through the New Year, Scratch for the Best Gift! - Absin (absin) Official Website

      That's all for today's explanation. If you have any experimental questions, you are welcome to join the group for discussion!

       

      Xiao Ai's Recommendation for This Issue

      Catalog Number Product Name Specification Application

      abs50061

      Cell Migration Analysis Kit (24-well plate, 8µM)

      200T

      Cell migration analysis

      abs50062

      Cell Invasion Analysis Kit (24-well plate, 8µM)

      200T

      Cell invasion analysis

      abs9490

      Matrigel (Standard, with phenol red)

      1.5mL×4

      Vascular generation; cell invasion 

      abs9491

      Matrigel (Standard, without phenol red)

      1.5mL×8

      abs9492

      Matrigel (High concentration, with phenol red)

      1.5mL×8

      Mouse skin tumor formation; gel plug

      abs9493

      Matrigel (High concentration, without phenol red)

      1.5mL×4

      abs9494

      Matrigel (Low factor, with phenol red)

      1.5mL×4

      Organoid culture; related research with growth factors, signaling pathways

      abs9495

      Matrigel (Low factor, without phenol red)

      1.5mL×4

      abs9497

      Matrigel (High concentration, low factor, with phenol red)

      1.5mL×8

      Mouse skin tumor formation; gel plug; related research with growth factors, signaling pathways

      abs9498

      Matrigel (High concentration, low factor, without phenol red)

      1.5mL×8

      abs9496

      Matrigel (IPS certification without phenol red)

      1.5mL×4

      Coated plate, suitable for hES cell expansion, induction of pluripotent stem cells (iPS) expansion and maintenance

      abs9410

      Ready-to-use Matrigel

      100mL

      Coated plate, suitable for difficult-to-adhere cells (e.g., 293T, HUVEC) expansion and maintenance

       

      Absin provides antibodies, proteins, ELISA kits, cell culture, detection kits, and other research reagents. If you have any product needs, please contact us.

      Absin Bioscience Inc.
      Email: worldwide@absin.net

      Follow us on Facebook: Absin Bio

      Ordering Details

      Email: worldwide@absin.cn

      Thanks for your interesting of our products, we will reply to you in 1-2 working days.

      • Products
      • Resources
      • Product Application
      • Calculation Tools
      • FAQs
      • Citations
      • Electronic Documents
      • About us
      • Company Profile
      • Ordering Tools
      • Customer Support
      • Contact us
      Email: worldwide@absin.cn
      picture invalid picture invalid
      ICP:16001690 Absin Bioscience Inc.All rights reserved.